Do I need to use a specific type of Steel?
What sectional properties, grades, etc are required?
What are the specifications and properties of the connection products used?
What design methodology is applied in the System?
Can the System be amended to operate to British Standards and/or Euro design codes?
How is the product/service procured?
What information is available for specifiers and design process consultation, etc?
Who does the design and provides/verifies the inputs?
How are Building Regulation checks, amendment and approval processes to be handled?
Will there be a Quality Management system?
What advisory or back up service is there?
Is the installation carried out purely by direct authorised installers?
What are the delivery and storage requirements?
Is there a health and Safety at Work policy and procedure?
What information is provided to site?
Can the system accommodate a range of common roof configurations?

Do I need to use a specific type of Steel?

Input material can vary according local requirements and or availability.

Hayes SFS will and has in the past re-engineered its systems to various input material qualities. E.g. G550 or G300 and the various coatings that these steels are supplied with, e.g. AZ150/200 for Zincalume or G350 for Galvanised... top

What sectional properties, grades, etc are required?

As each system is engineered and delivered with full sectional properties. These sectional properties are the basis for the many subsequent calculations required for generating tables and/or for the software to use when analysing Roof Truss members which it does from first principles.... top

What are the specifications and properties of the connection products used?

Hayes SFS uses non-proprietary connections which are readily available with ample data as to their performance, again Hayes SFS can engineer a system to suit a variety of connection methods. Hayes SFS also provides all connection details together with all tie down details required to achieve the relevant wind requirements.... top

What design methodology is applied in the System?

Roof Trusses are designed in HayesCAD Software from first engineering principles. Wall Frames are designed in HayesCAD Software based on Table Data developed by qualified Structural Engineers.

HayesCAD Software has been written and checked by qualified and experienced Programmers and Structural Engineers.

Section Properties and Tables are generated on a Project to Project basis and varying according to input material and connections methods..... top

Can the System be amended to operate to British Standards and/or Euro design codes?

Yes, BS has already being investigated and if required and on commencement of a UK based project the complete package will be modified to conform to any relevant codes.

This will involve a local accrediting Engineer with suitable credentials reviewing and endorsing the entire package.... top

How is the product/service procured?

The Hayes SFS is a licenced system to protect the technology and intellectual property within the systems provided.
These include:
Products – Hayes Patented Steel framing Products
HayesCAD – Computer detailing and design Software
HayesCAM – Production Optimisation Software
FrameWare – Machine Interface Software
Rollforming and Punching
Materials Handling

However there are no licence fees once the entire system is purchased.... top

What information is available for specifiers and design process consultation, etc?

Hayes SFS provide complete onsite training is all areas of the system, including HayesCAD. Training Manuals and references are also provided. These include a specification document for Designers and Architects..... top

Who does the design and provides/verifies the inputs?

HayesCAD is used to reduce all designs into wall panels, Roof Trusses and floor member layouts and detailed elevations.

This ideally is performed inhouse……..but the package is AutoCAD similar, and can be provided to outside detailers, under licence, if required..... top

How are Building Regulation checks, amendment and approval processes to be handled?

This will vary from location to location and customer to customer.
For our current Australian customer,

The System is accredited and endorsed by a suitably accredited local Engineer. Provided the customer designs within that scope then all applications will fall within that endorsement.

In addition, Hayes SFS has established an Engineering Accreditation and Design Service (EADS). Every steel frame detail generated by the Customer is forwarded to Hayes SFS and is check against the scope of the system and for detailing errors.

If the project is within scope then an individual Certificate is issue, if not, then Design services are available to ensure that any out of scope elements of the project meet the relevant standards which the System was delivered under.

This service can be endorsed by a suitably accredited local engineer or can be managed by the customer directly.... top

Will there be a Quality Management system?

Further to above, the system process will vary from system to system and Quality assurance can be provided once the scope has been set, Again, this is an area which can be managed by the customer as there may already be in place other management systems which the Hayes SFS systems can be integrated with..... top

What advisory or back up service is there?

Further to our EADS service, Hayes SFS is part of the Hayes International and Bradbury Group of companies which has offices worldwide. Advice and Service is always available.... top

Is the installation carried out purely by direct authorised installers?

The finished product is not handled any different to any other Steel Truss of Wall panel. As per local requirements... top

What are the delivery and storage requirements?

Depending on the input material used, most coated steel products are all weather.

Is there a health and Safety at Work policy and procedure?

Nothing which would require any further consideration over current industry practices, which vary from location to location.... top

What information is provided to site?

This will vary according to the end user however typically, Frame and truss layout plans showing the location of all assembled wall panels and roof trusses, any specific details, such as beams, standard connection details and tie down details

Can the system accommodate a range of common roof configurations?

The system allows for enormous flexibility as can be demonstrated by the variety of designs achieved by our customers in Australia and in China... top


Copyright 2005 Hayes Steel Framing Systems - All rights reserved | Website design by Cox Web & Design